What was found
FOUND MULTIPLE SPOTS OF CORROSION ON THE RT PRESSURE FLOOR SUPPORT BTWN BS 484 AND 513. BLENDED MULTIPLE SPOTS OF CORROSION ON THE RT PRESSURE FLOOR SILL BTWN BS 484 & 513 REF SRM 51-21-06. PERFORMED UT REMAINING THICKNESS MEASUREMENT IAW NDTM PART 4, 51-00-001, & FOUND TO BE ACCEPTABLE IAW REO 601R-53-41-666, REV-. PERFORMED EDDY CURRENT INSPECTION IAW NDTM PART 1, 51-20-06, & NDTM PART 6, 53-00-096, NO CRACKS FOUND. RESTORED SURFACE FINISH IAW SRM 51-21-16. COMPLIED WITH TASK CARD 51-900-1003-SKY.