Service difficulty report · Control Valve · Cndair CL6002C10

Difficulty date
October 22, 2026
Submitted
October 24, 2026
Operation
Air carrier
Aircraft
N701SK
Make and model
Cndair CL6002C10
Aircraft serial
10133
Aircraft time
51,640 hours, 34,052 cycles
Part
Control Valve
Part number
MS9068033
Condition
Smoke
Location
Zone 100
Stage of operation
CL
How discovered
O
Nature of condition
B
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHITE SMOKE FILLED COCKPIT DURING CLIMB, WENT AWAY AND CLEARED ABOUT 5 MINUTES LATER ON FINAL, THE SMOKE REAPPEARED & CLEARED AGAIN AND ONE LAST TIME DURING TAXI IN, ON ARRIVAL TO GATE LT AUTO PACK FAIL CAUTION MESSAGE. APPEARED FLIGHT 4941. R & R LT AIR CYCLE MACHINE IAW AMM 21-51-08, PERFORMED LEAK CHECK OF THE AIR DISTRIBUTION SYSTEM IAW AMM 21-51-00, NO LEAKS FOUND. PERFORMED AN OPS CHK OF AIR CONDITIONING SYS IAW AMM 21-51-00, OPS CHKD GOOD, NO LT PACK CAUTION OR ANY CORRELATING FAILURE MESSAGES FOUND. WENT INTO THE MDC AND PERFORMED THE ACSC 1 SELFTEST IAW AMM 45-45-00. TEST PASSED.