SDR SWIA95551

Service difficulty report · Annunciator · Emb EMB120ER

Difficulty date
April 5, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N193SW
Make and model
Emb EMB120ER
Aircraft serial
120088
Engine
Pwa PW118A
Part
Annunciator
Part number
3069001005
Condition
Failed
Location
Te Flaps
Stage of operation
LD
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

CONTROL FAULT ON OUTBD FLAP. CONTROL FAULT WILL NOT RESET. CHECKED CONNECTOR AT OUTBOARD ACTUATORS. FOUND GOOD. CYCLED FLAPS AND RECEIVED A CONTROL FAULT (INTERMITTENTLY) WITH OUTBOARD SEGMENTS FLASHING. RESET USING OVERRIDE SWITCH. SUSPECT BAD ANNUNICATOR PANEL. REPLACED FLAP ANNUNCIATOR PANEL ASSEMBLY. OPERATED FLAPS TEN TIMES. OPS CKS GOOD.

More about the Emb EMB-120ER