SDR SWIA95571

Service difficulty report · Hyd Pump · Swrngn SA227AC

Difficulty date
May 2, 1995
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N176SW
Make and model
Swrngn SA227AC
Aircraft serial
AC591
Engine
Garrtt TPE33111U
Part
Hyd Pump
Part number
PV304426
Condition
Failed
Location
Nr 1
Stage of operation
CR
Nature of condition
K, J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AIRCRAFT LOST ALL HYDRAULIC PRESSURE. BOTH LIGHTS ILLUMINATED AND GAUGE AT ZERO. EXTENDED GEAR PER EMERGENCY CHECK LIST. REPLACED THE NR ONE HYDRAULIC PUMP. PURGED AND SERVICED HYDRAULIC SYSTEMS. RAN THE LEFT AND RIGHT ENGINES. CYCLED FLAPS AND RESERVICED. LEAK CHECKED NR ONE HYDRAULIC PUMP. HYDRAULIC SYSTEM OPERATIONALLY CHECKS GOOD.