What was found
LT 14TH STAGE DUCT WARNING, FOLLOWED BY LT JET PIPE OVERHEAT MESSAGE. REPLACED AFT CLAMP ON LT 14TH STAGE BLEED AIR SHUT-OFF VALVE. RAN LT 14TH STAGE BLEED AIR AND LEAK CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
LT 14TH STAGE DUCT WARNING, FOLLOWED BY LT JET PIPE OVERHEAT MESSAGE. REPLACED AFT CLAMP ON LT 14TH STAGE BLEED AIR SHUT-OFF VALVE. RAN LT 14TH STAGE BLEED AIR AND LEAK CHECK GOOD.