SDR SWIA971711

Service difficulty report · Sensor · Emb EMB120ER

Difficulty date
February 25, 2000
Submitted
March 26, 2000
Operation
Air carrier
Aircraft
N584SW
Make and model
Emb EMB120ER
Aircraft serial
120352
Engine
Pwa PW118B
Part
Sensor
Condition
Intermittent
Location
Rt Mlg
Stage of operation
CL
Nature of condition
F, N
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RIGHT MAIN GEAR A INTRANSIT LIGHT WOULD NOT EXTINGUISH ON GEAR RETRACTION. CYCLED GEAR TWICE WITH SAME RESULTS.. RETURNED TO PSP. TROUBLESHOOTING OF RIGHT MAIN GEAR A INTRANSIT. FOUND RIGHT GEAR PROXIMITY SENSOR INTERMITTENT. INSTALLED SERVICEABLE PROXIMITY SENSOR PER MM 326101. OPS CHECKS GOOD.

More about the Emb EMB-120ER