SDR SWIA972074

Service difficulty report · Pressure Switch · Emb EMB120ER

Difficulty date
November 2, 2000
Submitted
November 7, 2000
Operation
Air carrier
Aircraft
N250YV
Make and model
Emb EMB120ER
Aircraft serial
120250
Aircraft time
18,045 hours, 25,467 cycles
Engine
Pwa PW118B
Part
Pressure Switch
Condition
Malfunctioned
Location
Cockpit
Stage of operation
CL
How discovered
O
Nature of condition
O
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AUTO PRESSURIZATION WOULD NOT PRESSURIZE NORMALLY. RETURNED TO PDX. AUTO PRESSURIZATION CHECKS COMPLIED WITH ON GROUND. OPS CHECKS OK AT THIS TIME.

More about the Emb EMB-120ER