SDR SWIA972081

Service difficulty report · Regulator · Emb EMB120RT

Difficulty date
November 6, 2000
Submitted
November 13, 2000
Operation
Air carrier
Aircraft
N156CA
Make and model
Emb EMB120RT
Aircraft serial
120156
Aircraft time
26,885 hours, 31,422 cycles
Engine
Pwa PW118
Part
Regulator
Condition
Out Of Adj
Location
Oil Pressure
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

PILOT REPORTED LOSS OF OIL PRESSURE (DROPPED IN YELLOW BAND) AND LOSS OF POWER (LEFT). DIVERTED TO EUGENE. ADJUSTED OIL PRESSURE REGULATOR PER MM 72-1-50. OPS AND LEAK CHECKS GOOD. REPLACED LEAKING FUEL OIL HEATER PER MM 72-01-40. OPS AND LEAK CHECKS ON GROUND. PERFORMED HIGH POWER RUNS FOR 10 MINUTES. NO SYSTEM DEFECTS NOTED.

More about the Emb EMB-120RT