SDR SWIA972297

Service difficulty report · Control Unit · Emb EMB120ER

Difficulty date
January 27, 2001
Submitted
January 29, 2001
Operation
Air carrier
Aircraft
N293SW
Make and model
Emb EMB120ER
Aircraft serial
120320
Aircraft time
11,093 hours, 15,977 cycles
Engine
Pwa PW118A
Part
Control Unit
Condition
Failed
Location
Te Flaps
Stage of operation
CL
How discovered
O
Nature of condition
F
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHEN SELECTING FLAPS UP AFTER TAKEOFF HAD A CONTROL FAULT FOR THE OUTBOARD FLAPS. FOLLOWED QRH PROCEDURE BUT WOULD NOT RESET. RETURNED TO SFO. REPLACED FLAPS CONTROL UNIT. FLAP SYSTEM OPS CHECKS OK. P/N ON: 347-200-1001, S/N ON: 0034.