SDR SWIA972575

Service difficulty report · Pressure Switch · Emb EMB120ER

Difficulty date
May 14, 2001
Submitted
May 17, 2001
Operation
Air carrier
Aircraft
N568SW
Make and model
Emb EMB120ER
Aircraft serial
120343
Aircraft time
6,779 hours, 9,901 cycles
Engine
Pwa PW118B
Part
Pressure Switch
Condition
Faulty
Location
Hyd System
Stage of operation
DE
How discovered
O
Nature of condition
J
Precautionary procedure
O

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

RUDDER OVERBOOST LIGHT ILLUMINATED ON DESCENT. FOLLOWED QRH. REPLACED RELAYS K0331, K0319, K0323, K0317, DID NOT SOLVE PROBLEM. REPLACED NR 1 AND 2 AIRSPEED INDICATORS WITH SERVICEABLE UNIT. DID NOT FIX PROBLEM. REINSTALLED NR 1 AND 2 AIRSPEED INDICATORS TO ORIGINAL POSITIONS. BOTH AIRSPEED INDICATORS OPS CHECK GOOD MM 34-12-00. PERFORMED OVERBOOST FAULT ISOLATION MM CHECKS, STEPS 1 THRU 2, 3, AND 4. REMOVED AND REPLACED GREEN SYSTEM PRESSURE SWITCH. PROBLEM STILL EXISTS. REMOVED AND REPLACED RUDDER CONTROL SWITCH S0449 (GREEN SYSTEM SWITCH). OPS CHECKED SYSTEM AND FOUND NORMAL. OVERBOOST LIGHT DID NOT ILLUMINATE. NO LEAKS NOTED AT THIS TIME.GREEN PRESSURE SWITCH P/N 1206P0114-01.

More about the Emb EMB-120ER