SDR SWIA972635

Service difficulty report · Bleed Valve · Cndair CL6002B19

Difficulty date
June 15, 2001
Submitted
June 19, 2001
Operation
Air carrier
Aircraft
N413SW
Make and model
Cndair CL6002B19
Aircraft serial
7102
Aircraft time
14,655 hours, 13,177 cycles
Engine
Ge CF34*
Part
Bleed Valve
Condition
Failed
Location
Apu
Stage of operation
CR
How discovered
O
Nature of condition
J
Precautionary procedure
A

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

WHEN CONDUCTING THE SINGLE PACK SWITCH OVER FROM THE APU TO THE RIGHT 10TH STAGE AS PER THE PROCEDURE IN THE MEL, THE RIGHT 10TH STAGE BLEED VALVE WOULD NOT OPEN. RETURNED TO THE FIELD DUE TO LEFT A/C PACK BEING DEFERRED. C/W OPS CHECK OF 10TH STAGE BLEED VALVES, APU BLEED VALVES AND 10TH STAGE ISOLATION VALVES. ALL CHECK GOOD AT THIS TIME. LEFT PACK REPLACED.