What was found
FLOORBEAM CROSS MEMBER AT STA 349 BETWEEN LBL 27.00 AND LT FUSELAGE SIDE HAS CORROSION PAST SERVICE LIMITS. REPLACED FLOORBEAM STRAP BETWEEN LBL 27.00 AND FUSELAGE SIDE ON FS 349 IAW SRM 51-40-00.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FLOORBEAM CROSS MEMBER AT STA 349 BETWEEN LBL 27.00 AND LT FUSELAGE SIDE HAS CORROSION PAST SERVICE LIMITS. REPLACED FLOORBEAM STRAP BETWEEN LBL 27.00 AND FUSELAGE SIDE ON FS 349 IAW SRM 51-40-00.