What was found
OBSERVED LIGHT CORROSION (WHILE VISUALLY INSPECTING) ON THE AREA BELOW THE LAVATORY FLOOR PANEL AND TOWARD THE PASSENGER DOOR FLOOR PANEL BETWEEN LAVATORY AND PASSENGER DOOR ENTRANCE. REMOVED AND REPLACED RIGHT AND LEFT BUTT STRAPS UNDER GALLEY AND LAVATORY AREA. REMOVED CORROSION BETWEEN LAVATORY AND PASSENGER DOOR AREA, ALODINED, AND PRIMED, IAW SRM 51-00-00.