What was found
AFTER A BANG HEARD DURING CLIMB, FWD EQPT OVHT DISPLAYED AND OVHT LGT ILLUM AFTER SELECTOR WAS POSITIONED TO STBY, LGT REILLUM FOLLOWING 5MIN DELAY AFTER SELECTOR WAS POSITIONED TO OVRD. EICAS MSG FWD EQPT COOLING DISPLAYED AND NO COOLING LGT ILLUM. WX FAIL AND HSD ALTITUD COLORS WENT BLACK. INDICATIONS NORMAL. OVERWEIGHT LANDING. THE LANDING WAS SMOOTH AND BRAKES TEMP DID NOT EXCEED 4 ON BTMS. RT MIX-AIR CONDITIONING MANIFOLD OULET DUCT FOUND BROKEN. AFT RT AIR DISTRIBUTION S/O VALVE CLOSED AFT ZONE TRIM AIR MODULATION VALVE CLOSED IAW MEL 21-51-6-2 PROCEDURES. PERFORMED CHECK IAW MFG AMM 21-58-00 PAGE 501. CHECK RESULTS OK. NOTE: ONLY ONE PACK OPERATION.