As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
BOSTON - NR 3 ENGINE SHUT DOWN ON TAKEOFF AT 375 FEET AGL. RETURNED TO BOSTON TO GATE. WINDMILLING OIL PRESSURE - 20 PSI FOR 14 MINUTES. REPLACED NR 3 FUEL PUMP PER MM 73-11-1 - NORMAL RUN. FUEL PUMP SHAFT SHEARED. FUEL CONTROL UNIT CHANGED - PRECAUTIONARY. (X)