As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
C-2 CARGO DOOR BUNGEE TORQUE SHAFT ATTACHMENT BRACKET AT FLOOR BEAM FLANGE HAS 6.5 INCH CRACK AT STATION 950E. PERFORMED CABIN FLOOR BEAM REPAIR AT STATION 950E, REPAIRED LOWER FLANGE IAW STRUCTURAL REPAIR MANUAL CHAPTER 53-10-8. REPLACED AFT CARGO DOOR FORWARD BUNGEE CABLE, C-2 DOOR OPERATION CHECK NORMAL PER MM 52-35-31. (M)