As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
NOSE GEAR WOULD NOT COME UP ON DEPARTURE. GREEN LIGHT WENT OUT, RED AND AMBER LIGHTS CAME ON. THERE WAS NO SOUND OF NOSE GEAR GOING INTO WELL. PLACED HANDLE DOWN AND GOT 3 DOWN GREEN INDICATION. TRIED TO RAISE A SECOND TIME WIH SAME RESULTS. REMOVED AND REPLACED NLG ACTUATOR IAW A300 MM 32-31-22, OPS CHECK GOOD IAW A300MM 32-30-00.