As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FS 280 OUTBD CLIP CRACKED AT LBL9. DRILLED UP NEW ATTACH ANGLE FOR FLOOR PANEL 221AF. WAITING FOR REPIR OF 280 FOR INSTALLATION. ALL WORK DONE IAW CRJ200 SRM 51-40-11 DK 7022603 INSTALLED NEW AFT ATTACH ANGLE IAW SRM 51-42-06. INSTALLED CAMLOCK RECEPTACLES IAW SRM 51-42-06 CM 20420 JOB COMPLETE (CLOSED)