What was found
FOUND CORROSION ON PRESS DECK AT FS455 - BL44 LT, (RESOLVED ON W/O: 22159 TASKCARD: N/R-00219). BLENDED CORRODED AREA IAW CRJ 200 SRM 51-41-45 REQUEST THICKNESS CHECK OF BLENDED AREA DK 7022603. C/W THICKNESS CHECK AT BLENDED AREA IAW CRJ 200 NDT MANUAL 51-20-04 PART 1, MINIMUM THICKNESS IS .051". C/W EDDY CURRENT INSPECTON OF REWORKED AREA PER REO601R-53-41-412 IAW CRJ 200 NDTM 51-20-06. NO DEFECTS NOTED. FASTENERS BLENDED ARE INSIDE THE ACCEPTED LIMITS ALSO REPAINTED THE SURFACES PER REO601R-53-41-412 BAT23167RII REQUIREMENTS SATISFACTORY PER SP607. COMPLIED WITH EC/TC REO 601R-53-41-412.