What was found
CORROSION ON DOUBLER AT FS 498-513 - BL42-44LT (RESOLVED ON W/O: 22159 TASKCARD: N/R-00226 ). BLENDED CORRODED AREA ON DOUBLER AT FS 498-513-BL42-44LT IAW CRJ 200 SRM 51-41-45 REQUEST THICKNESS CHECK OF BLENDED AREA ALSO AROUND 491.5 OF PRESSURE DECK DK 7022603. C/W THICKNESS CHECK AT BLENDED AREA IAW CRJ 200 NDT MANUAL 51-20-04 PART 1, MINIMUM THICKNESS IS .077". C/W EDDY CURRENT INSPECTION OF REWORKED AREA PER REO601R-53-41-412 IAW CRJ 200 NDTM 51-20-06. NO DEFECTS NOTED. REMOVED AND REPLACED ONE FASTENER ALL OTHERS WITHIN LIMITS REPAINTED SURFACE PER REO 601R-53-41-412 AND CRJ 200 SRM 51-42-06 BAT23167. RII REQUIREMENTS SATISFACTORY PER SP607. COMPLIED WITH EC/TC REO 601R-53-41-412.(SUPPLEMENTAL SDR 4