What was found
LT FS 536 PRESSURE DECK CORRODED AT NUTPLATE (RESOLVED ON W/O: 22159 TASKCARD: N/R-00247. BLENDED CORROSION ON PRESSURE DECK IAW CRJ 200 SRM 51-41-45 REQUEST THICKNESS CHECK OF BLENDED AREA. C/W THICKNESS CHECK AT BLENDED AREA IAW CRJ 200 NDT MANUAL 51-20-04 PART 1, MINIMUM THICKNESS IS .050" C/W EDDY CURRENT INSPECTION OF REWORKED AREA PER REO601R-53-41-412 IAW CRJ 200 NDTM 51-20-06. NO DEFECTS NOTED. FASTENERS BLENDED ARE INSIDE THE ACCEPTED LIMITS ALSO RESTORED THE FINISH PER REO 601R-53-41-412 SM 7023171RII REQUIREMENTS SATISFACTORY PER SP607. COMPLIED WITH EC/TC REO 601R-53-41-412 .