What was found
LT O/B 484 IS CRACKED. CUTAWAY DAMAGED FLANGE IAW REO 601R-53-41-059. REF NDT OF CUTOUT ON W/C 237. DEBURR CUT, ALODINE, PRIME/TOPCOAT CUTLINE. MADE NEW CLIP. LOCATE HOLES, DEBURR ALL, TOUCHUP ALODINE, PRIME/TOPCOAT. INSTALLED NEW CLIP IN WET WITH SOLID RIVETS/HI-LITE PINS, PRIME/TOPCOAT FASTENERS. APPLIED DYNATROL CORROSIVE/WATER INHIBITING COMPOUND TO REWORK AREA. REWORK DONE IAW REO 601R-53-41-059. (CLOSED)