As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOORBEAM SUPORT BRACKET IB OF RBL 9 CRACKED AT FS 461. REMOVED SUPPORT FITTING AT OTBD. SIDE OF RBL 9.0 AT STA. 461, DRILLED UP NEW FITTING AND STARTED INSTALLING FASTNERS, REMOVED ACCESS PANEL THRU PRESS. FLOOR FOR ACCESS OF AFT END HORZ. FASTNERS REF. SRM 51-42-21 6/5/06 20423.FINISHED INSTALLING FASTNERS ON O/B SIDEOF RBL 9.0 AT STA. 461, REINSTALLED ACCESS PANELS THRU PRESSURE FLOOR IAW CRJ 200 SRM 51-42-21 06-06-06 JOB COMPLETED. (CLOSED)