What was found
RANRC 268, FLOORBEAM LBL 27 OUTBOARD AT APPROX 310 HAS CRACK PROTRUDED FROM RIVET, MARKED. CUT-OUT APPX 2IN OF DAMAGED WEB FLANGE AT LBL 27.0, FWD OF F.S. 310 IAW CRJ SRM 51-71-59. FABRICATED REPAIR ANGLE FROM 2024-T3 .040 PO 864-3-1 AND REPAIR FILLER IAW CRJ SRM 51-71-59. LOCATED & DEBURRED FASTENER HOLES IN REPAIR ANGLE, REPAIR FILLER & WEB IAW CRJ SRM 51-40-11. OK TO ALODINE, PRIMED, AND PAINT REPAIR ANGLE AND REPAIR FILLER. ALODINED, PRIMED, & PAINTED, REPAIRED ANGLE AND REPAIR FILLER IAW CRJ SRM 51-25-16. OK TO INSTALL REPAIR ANGLE & REPAIR FILLER. INSTALLED REPAIR ANGLE & FILLER IAW CRJ SRM 51-71-59. FOUND REPAIR INSTALLATION UNSERVICEABLE REFERENCE W/C 515 FOR CORRECTIVE ACTION. (CLOSED)