What was found
UPPER RADIUS CLIPS LEFT AND RIGHT OF THE CENTER OF FS 280 STRUCTURE ARE CRACKED. REMOVED RT I/B RADIUS CLIP. DUPLICATE LT CLIP. MATERIAL ID FROM CRJ SRM 53-21-43. OK TO PRIME AND PAINT. PRIMED AND PAINTED IAW CRJ SRM 51-25-06. OK TO INSTALL. INSTALLED LT CLIP IAW CRJ SRM 51-42-21. DUPLICATED RT CLIP. OK TO PRIME AND PAINT. PRIME AND PAINT CLIP IAW CRJ SRM 51-25-16. OK TO INSTALL. INSTALL CLIP IAW CRJ 51-42-21. (CLOSED 10/31/06)