What was found
RT BOX BEAM ACCESS PANEL CUTOUT CRACKED AT FWD NUT PLATE, REMOVED ANGLES AND MADE CUT ON RIGHT SIDE BOX BEAM IAW REO 601R-53-61-366. PERFORMED EDDY CURRENT INSPECTION OF CUT LINE & UPPER & LOWER ANGLE AT RT LOWER WEB ACCESS HOLE ON ENGINE SUPPORT BEAM BETWEEN FS 625.30 & FS 640.00. NO DEFECTS NOTED. FABRICATED NEW RT WEB & STARTED PICKING UP HOLES IAW REO 601R-53-61-366. FABRICATED AND DRILLED UP RT INNER DOUBLER AND RT ANGLES AND DOUBLER SPLICE IAW REO 601R-53-61-366. STEPPED UP HOLES ON DOUBLER SPLICE, INNER DOUBLER, AND ANGLES IAW REO 601R-53-61-366. PARTS SENT TO PAINT SHOP. PRIMED & PAINTED DOUBLERS SPLICES AND ANGLES IAW CRJ SRM 51-25-01. STARTED INSTALLING DOUBLER, SPLICE AND ANGLES ON RT LOWER