As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
LEFT FS 621.00 FLOORBOARD ANGLE CRACKED AT LBL 36.00 REO REPAIR 601R-53-61-117. REMOVED FASTENERS FOR REO 601R-53-61-117 FABRICATED REPAIR PARTS IAW REO 601R-53-61-117 USING P/N 601R35031-241 FLOORBEAM ANGLE. DH752 TOUCHED UP FINISH AT CUTLINE PER CRJ SRM 51-25-16. OK TO INSTALL. WET ASSEMBLED ALL ITEMS PER SRM 51-23-00 IAW REO 601R-53-61-117. OK TO SEAL AND PAINT APPLIED SEALANT AND TOPCOAT IAW CRJ SRM 51-23-00 AND 51-25-16. (CLOSED 11/15/06)