What was found
RT WING, OUTB FLAP, FLAP BEAM AT RIB 14 AFT PICK UP, CORROSION FOUND. REFER TO EXELTECH WORK PACKAGE YUL000164 NRTC 600-23 FOR ALL WORK ACCOMPLISHED. RT WING OUTBD FLAP, FLAP BEAM ATRIB 14 AFT PICK UP. CORROSION REMOVED AS PER SRM 51 21 42. AND FOUND WITH IN LIMIT S PER SRM 57 53 10 FIG 310 REPAIR DETERMINED NOT TO BE A MAJOR REPAIR IAW SP 663 AND FAR 43 APPENDIX A REPAIR ACCOMPLISHED IAW 57 55 10. MATERIA THICKNESS .475" MATERAIL REMOVED .001" WITHIN LIMITS AS PER SRM 57 55 10 FIG 310.