As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FLOOR SUPPORT STRINGER AFT CLEAT (CUT OUT CUP FOR HANDRAIL ARM) CORRODED. BLENDED AND REMOVED AFT CUP, FOUND TO BE OUT OF LIMITS PER CRJ 200 SRM 53-00-00 BAT 23167. DRILLED UP NEW AFT CUP REF CRJ-200 SRM 51-42-06, AND ADDED NEW NUT PLATES. INSTALLED NEW CUP ON STRINGER PER CRJ 200 SRM 51-42-06, BAT23167 4/14/2007. SUPPLEMENTAL - SDR CLOSED 04/16/07.