What was found
CORROSION ON FLOORBEAM BETWEEN FS 559.00 + 80 TO FS 559.00 + 112 RBL 27. [SUP 05-15-07] CORROSION ON FLOOR BEAM BTWN FS 559.00 + 80 TO FS 559.00 +112 RBL 27 REMOVED AS PER 51-21-06. ALODINED, PRIMED AND PAINTED AS PER SRM 51-21-11.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CORROSION ON FLOORBEAM BETWEEN FS 559.00 + 80 TO FS 559.00 + 112 RBL 27. [SUP 05-15-07] CORROSION ON FLOOR BEAM BTWN FS 559.00 + 80 TO FS 559.00 +112 RBL 27 REMOVED AS PER 51-21-06. ALODINED, PRIMED AND PAINTED AS PER SRM 51-21-11.