What was found
FS 280 FLOOR SUPPORT ANGLE IS CRACKED, JUST O/B OF THE LBL 27.0. FABRICATED NEW O/B CLIP LBL 9, AND LOCATED HOLES, IAW CRJ SRM 51-24-26 AND 51-40-11. 06/28/07 INSTALLED CLIP, IAW CRJ SRM 51-42-06 AND 51-42-21. 06/28/07, AT FS 280 LBL 9. SUPPLEMENTAL - SDR CLOSED 07/03/07.