What was found
SUSPECTED CRACK ON INTERCOSTAL UPPER RADIUS AT FS 484 RBL 27 O/B. LPI WAS PERFORMED ON THE CLIP UPPER RADIUS AT FS 484 RBL 27, O/B IAW NDTM 51-20-08 AND FOUND TO BE CRACKED IN THE UPPER RADIUS, APPROX 1/4". REMOVED DAMAGED CLIP AT FS 484 RBL 27 O/B AND DUPLICATED PART FROM PRE-FORMED STOCK P/N S-6144-3 FROM PO 950007 IAW CRJ 200 SRM 51-40-06, 51-40-11 AND BOMBARDIER DWG NR S6144. OK TO TREAT AND PRIME. ALODINED AND PRIMED IAW CRJ 200 SRM 51-21-11 AND 51-25-06. OK TO INSTALL. INSTALLED DUPLICATED CLIP AT FS 484 RBL 27 O/B IAW CRJ 200 SRM 51-42-21. SUPPLEMENTAL - SDR CLOSED 07/18/07