What was found
AAR - RIGHT O/B INTERCOSTAL AT FS 484 CRACKED. CUT AWAY DAMAGED (CRACKED) ATTACHMENT FLANGE AT FS 484.00 O/B SIDE RIGHT INTERCOSTAL IAW REO 601R-53-41-059. (FABRICATED) ANGLE CLIP FROM 2024 T-3 .063" (PO 950261). COMPLIED WITH LPI OF CUT LINE AND FABRICATED ANGLE IAW REO 601R-53-41-059. NO DEFECTS NOTED ANGLE CLIP REQUIRES DRILLED AND CONFORMED. LOCATED HOLES AND CONFORMED ANGLE IAW REO 601R-53-41-059 OK TO ALODINE AND PRIME. ALODINED AND PRIMED IAW CRJ 200 SRM 51-25-06. OK TO INSTALL. INSTALLED SERVICEABLE INTERCOSTAL AT RIGHT O/B FS 484 IAW REO 601R-53-41-059. OK TO TOP COAT. TOP COATED IAW CRJ 200 SRM 51-25-16. SUPPLEMENTAL - SDR CLOSED 09/12/07.