What was found
ETNRC - LEFT STRINGER CLIP AT FR 38 AND STRINGER 21L FOUND CORRODED. CORROSION REMOVED ON LT STR CLIP AT FR 38 AND STR 21L IAW SRM 51-21-42. FABRICATION LT STR CLIP AT FR 38 AND STR 21L COVER W/C 2000-63. LT STR CLIP REPLACED IAW SRM 51-25-01 AND 51-25-03. REPAIR DETERMINED NOT TO BE A MAJOR REPAIR IN ACCORDANCE WITH S.P. 663 AND FAR 43, APPENDIX A. REPAIR ACCOMPLISHED IN ACCORDANCE WITH SRM 51-21-42 MATERIAL THICKNESS: 0.063 MATERIAL REMOVED: 0.013 WITHIN LIMITS AS PER SRM: OUT LIMITS AS PER SRM 53-61-00 FIG 301.