What was found
ON MLG SKIN CORRODED AT FR 27 BL 0. CORROSION REMOVED ON MLG SKIN AT FR 27 BL 0 IAW SRM 51-21-42 U/T PERFORMED IAW NTM NOM=0.063" MIN=0.060". REPAIR DETERMINED NOT TO BE A MAJOR REPAIR IN ACCORDANCE WITH SP 663 AND FAR 43, APPENDIX A. REPAIR ACCOMPLISHED IN ACCORDANCE WITH SRM 51-21-42 MATERIAL THICKNESS: 0.063. MATERIAL REMOVED: 0.003 WITHIN LIMITS AS PER SRM: 53-51-00 FIG 301. SUPPLEMENTAL - SDR CLOSED 11/01/07.