What was found
FS 280 RBL 9 ANGLES CRACKED IB AND OB, RESOLVED ON W/O: 75509 TASKCARD: N/R-00248). REMOVED 280 RBL 9 CRACKED ANGLE CLIPS I/B AND O/B. FABRICATED SERVICEABLE CLIP ANGLES. REFER TO FORM 412 IAW CRJ 200 SRM 53-21-43 AND 51-24-21. OK TO TOPCOAT FASTENERS APPLIED TOPCOAT TO FASTENERS AND REPAIR AREA IAW CRJ 200 SRM 51-25-16. INSTALLED DRIP TRAY (REF 409A) IAW CRJ 200 SRM 51-42-13 USING CR 3552-4-2.