What was found
FOUND FR 23B CORRODED ON LWR FLANGE BTW STR 21L-21R. FR 23B ON LWR FLANGE BTW STR 21L - 21R CORROSION IS REMOVED IAW SRM 51-21-42 AND FOUND OUT OF LIMITS SRM 53-51-00 U/T PERFORMED BY HEATHAIR AMO46-90 W/O 37934 IAW NTM MIN = 0.035" FRAME 23B ON LWR FLANGE BTW STR 21L - 21R REPAIRED IAW SRM 53-00-00 FIG 430 SHEET 1FABRICATION COVER ON W/C 2000-232 MATERIAL THICKNESS: 0.063 MATERIAL REMOVED: 0.028 WITHIN LIMITS AS PER SRM: 53-51-00 FIG 301.