Service difficulty report · Floor Support · Cndair CL6002B19

Difficulty date
March 6, 2008
Submitted
March 12, 2008
Operation
Air carrier
Aircraft
N917EV
Make and model
Cndair CL6002B19
Aircraft serial
7769
Aircraft time
12,376 hours, 10,623 cycles
Part
Floor Support
Condition
Cracked
Location
Fuselage
Stage of operation
IN
How discovered
V
Nature of condition
O
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FS 280 AFT FLOOR SUPPORT ANGLE IS CRACKED AT LBL 9. JOB COMPLETE. REFER TO M-234 FORM STEPS 2 THRU 9 FOR CORRECTIVE ACTION. CUT AWAY DAMAGED SECTION OF 280 AFT FLOOR SUPPORT ANGLE IAW REO 601R-53-11-138. PERFORMED NDT ON CUTLINE PER REO 601R-53-11-138 NO DEFECTS NOTED AT THIS TIME PER NDTM 51-20-08. FABRICATED -3 AND -5 REPAIR ANGLES IAW REO 601R-53-11-138. HEAT TREAT REQUIRED. HEAT TREATED FABRICATED -3 & -5 ANGLES TO T62 CONDITION AS PER CRJ 200 SRM 51-24-06. HARDNESS TEST GOOD. DRILLED AND FIT -3 & -5 REPAIR ANGLES IAW REO 601R-53-11-138 READY TO INSTALL. FABRICATED -1 FILLER ANGLE FROM NEW 600-3407-595 ANGLE IAW REO 601R-53-11-138. READY TO INSTALL. INSTALLED -1 FILLER ANGLE AND -3 & 5 REPAIR ANGLES IAW REO 601R-53-11-138 AND FS 280 CLIPS IAW CRJ SRM 51-42-21. JOB COMPLETE. SUPPLEMENTAL SDR CLOSED 3/12/08.