What was found
SURFACE CORROSION ON LEFT PRESSURE FLOOR LANDING FS 449.85 AT LBL 45. REMOVED CORROSION PER SRM 53-41-45. COMPLIED WITH UT THICKNESS CHECK IAW NDTM 51-20-04. FOUND BLENDED AREA MINIMUM THICKNESS TO BE .068". PERFORMED EDDY CURRENT INSPECTION OF BLENDED AREAS IAW NDTM 51-20-06. NO DEFECTS NOTED. BLENDOUT OUT OF LIMITS IAW SRM 53-41-45. MAPPED DAMAGE & SUBMITTED PER SRM 51-13-00. R & R FASTENERS PER REO 601R-53-41-714, PRIMED AND PAINTED PER SRM 51-25-00. APPLIED A FILLET SEAL &CIC TO REWORK AREA. COMPLIED WITH EC/TC REO 601R-53-41-714.