What was found
CARGO DOOR FWD TRACK BOTTOM U CHANNEL IS CRACKED 1/4" LONG AT BOTTOM I/B RIVET. REMOVED CRACKED IAW SRM 51-42-06. LOCATED FASTENER HOLES IN NEW PART AND INSTALLED IAW SRM 51-40-11 AND 51-42-06. J. (B)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CARGO DOOR FWD TRACK BOTTOM U CHANNEL IS CRACKED 1/4" LONG AT BOTTOM I/B RIVET. REMOVED CRACKED IAW SRM 51-42-06. LOCATED FASTENER HOLES IN NEW PART AND INSTALLED IAW SRM 51-40-11 AND 51-42-06. J. (B)