What was found
BURNING SMELL IN FLT ACCOMPANIED BY RADIO ATL AT 20 FT GEAR HORN SINK RATE AND PULL UP AURAL. FLT 4268 DEL 104 MINS. (SERVICE LIGHTS) REMOVED AND REPLACED PYLON SERVICE LIGHT ASSY IAW CRJ700 AMM33-31. CBP2M7 PUSH IN, STAYS CLOSED, NO SMOKE, NO POPPING. OPERATION CHECKED GOOD, NO OTHER DEFECTS NOTED AT THIS TIME. INSPECTED CBP-2 AROUND CB-M7 PER CRJ700 AMM 05-21-00-210-801-A01. NO DEFECTS NOTED. REMOVED AND REPLACED PYLON SERVICE LIGHT ASSY IAW CRJ700 AMM 33-31. CBP2 M7 PUSH IN, STAYS CLOSED, NO SMOKE, NO POPPING, OPERATION CHECKED GOOD. NO OTHER DEFECTS NOTED AT THIS TIME.