What was found
JUST OUTBOARD LBL 9, FS 280 UPPER SILL CRACKED APPROX 1 INCH LONG AT MLG EMERGENCY RELEASE CABLE BRACKET. REMOVED MLG EMERGENCY RELEASE CABLE BRACKET IAW SRM 51-41-02. REPAIRED LBL 9 FS 280 UPPER SILL IAW REO 601R-53-11-138-NC AND DEVIATION REO 601R-53-11-1441. RE-INSTALLED MLG EMERGENCY RELEASE CABLE BRACKET IAW SRM 51-41-02. FUNCTIONAL TEST OF EMERGENCY GEAR EXTENSION DUE. PERFORMED FUNCTIONAL TEST OF EMERGENCY GEAR EXTENSION IAW AMM 32-34-00-720-801. FUNCTIONAL TEST OK AT THIS TIME. COMPLIED WITH ASA ECTC REO 601R-53-11-1441 IAW REO 601R-53-11-1441. COMPLIED WITH ASA EC-TC REO 601R-53-11-138. ASA RII COMPLIED WITH. (S)