What was found
WHILE IN CLIMB, NR 2 ENGINE TQ FLUX OF 10 PERCENT AT 1,000 FTS, AFTER TAKEOFF INCREASE 20-30 PERCENT. RETURNED TO AIRPORT AND IN FINAL WENT TO 0 PERCENT THEN BACK TO 78 PERCENT TWICE. ENGINE WAS SHUTDOWN. EMERGENCY LANDING PERFORMED. REMOVED AND REPLACED RT INBOARD TQ SENSOR AND CONNECTED GROUND WIRE ON PVM AS PER JIC 61-22-00, OPT CHECK FOUND OK. NO FLUX NOTED AS PER JIC 77-13-61. (M)