What was found
HALF OF AISLE PATH EVACUATION LIGHTS NOT WORKING ON BATTERY POWER. REPLACED AND TESTED EMERGENCY LIGHTS POWER SUPPLY 61WL BATTERY PACK AS PER MM 33-51-21 AND FOUND WORKING PROPERLY.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
HALF OF AISLE PATH EVACUATION LIGHTS NOT WORKING ON BATTERY POWER. REPLACED AND TESTED EMERGENCY LIGHTS POWER SUPPLY 61WL BATTERY PACK AS PER MM 33-51-21 AND FOUND WORKING PROPERLY.