What was found
DURING IDLE DESCENTS, BOTH HP VALVES ON, EXHAUST ODOR COMES THROUGH AIR SYS. R & I NEW PROBE DUMMY PLUG SEALS ON NR 2 ENGINE IAW MM 72-01-60. OPS CHECK GOOD NO EXHAUST ODORS AT THIS TIME. NO LEAKS NOTED AT PROBE.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING IDLE DESCENTS, BOTH HP VALVES ON, EXHAUST ODOR COMES THROUGH AIR SYS. R & I NEW PROBE DUMMY PLUG SEALS ON NR 2 ENGINE IAW MM 72-01-60. OPS CHECK GOOD NO EXHAUST ODORS AT THIS TIME. NO LEAKS NOTED AT PROBE.