What was found
ON POST FLT INSPECTION, FOUND UPPER LT GEAR DOOR MISSING. INSTALLED LT FOLDABLE MLG DOOR IAW SRM 52-81-00. GEAR SWING PERFORMED, OPS CHECK GOOD. REF JIC 07-11-00, JUP 10000.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
ON POST FLT INSPECTION, FOUND UPPER LT GEAR DOOR MISSING. INSTALLED LT FOLDABLE MLG DOOR IAW SRM 52-81-00. GEAR SWING PERFORMED, OPS CHECK GOOD. REF JIC 07-11-00, JUP 10000.