What was found
THE CREW REPORTED THE EXTERIOR SERVICE DOOR EMERGENCY EXIT FLOOD LIGHT INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. REPOSITIONED LIGHT BULB OF EMERGENCY FLOOD LIGHT UNDER SERVICE DOOR AND TESTED IAW JIC 33-50-00. THE OPS CHECK WAS GOOD. NO PARTS R & R. THE ACFT WAS RETURNED TO SERVICE.