Service difficulty report · Power Supply · Aerosp ATR72

Difficulty date
April 5, 2012
Submitted
April 6, 2012
Operation
Air carrier
Aircraft
N414WF
Make and model
Aerosp ATR72
Aircraft serial
414
Aircraft time
33,378 hours, 32,839 cycles
Part
Power Supply
Part number
3012000
Part serial
400201
Condition
Inoperative
Location
Emergency Lights
Stage of operation
IN
How discovered
C
Nature of condition
L
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

DURING MX, FOUND LEFT FORWARD EMERGENCY EXIT SIGNS INOPERATIVE. ACFT REMOVED FROM SERVICE. R & R POWER SUPPLY UNITS IAW JIC33-51-21, RAI10000 AND R & R THE POWER SUPPLY BATTERIES IAW RAI 10010. THE OPS CHECKED GOOD. ACFT RETURNED TO SERVICE.