What was found
DURING MX INSPECTION, FOUND HALF THE LIGHTS OF FOWARD AISLE EVACUATION PATH LIGHTS INOPERATIVE. THE ACFT WAS REMOVED FROM SERVICE. R & R THE FWD EMERGENCY LIGHT POWER SUPPLY 43WL AND CLEANED FLOOR PROXIMITY ESCAPE PATH STRIP LIGHT CONNECTOR 55WL(B) IAW JIC 33-51-21, RAI 10000 AND ASM 33-51-00. THE OPS TEST WAS SATISFACTORY. THE ACFT WAS RETURNED TO SERVICE.