What was found
8 AREAS OF CORROSION ON FWD PRESSURE BULKHEAD CONTACT POINTS. CLEANED CORROSION ON FWD PRESSURE BULKHEAD CONTACT POINTS IAW SRM51-21-42. TREATED AND PRIMED IAW SRM51-21-17, 51-21-27. ACCOMPLISHED ALL WORK IAW ATR-SRI-DO/TS-601/10-12927, REF SRAS-DO/TS-601/10. 5589 AND AE E0 NR E2-53MR-233, REF NDT REPORTS, 8 EA ATTACHED 8130S, 100128-35, 34,33,32,31,30,29,28.